Mandolex Interior Grade

Vibration Damping between 70 and 80 Hz

Description of Damping Coating

Vibration Decay Rate (dB/sec)

Description of Plate Steel (1mm)

Uncoated plate
1.5 mm (dry) Mandolex
3 mm (dry) Mandolex

3
115
224

Description of Plate Aluminimum (3 mm)

Uncoated plate
1.5 mm (dry) Mandolex
3 mm (dry) Mandolex

11
104
555

Toxicity


NES 713, Issue Toxicity Test. Toxicity Index 0.34. The Results of the quantitative analysis for toxcity show the following results:

N < 0.15%   C14.94%   S<0.15%

The results of the quantitive analysis for toxcity show the presence of:
C, O, AL, Si, K, Ca, Fe

Smoke Emission

When tested to BS 6853: 1999, Annex D8.4 'Panel Test'

 
 

Specimen 1

Specimen 2

Specimen 3

Ao (on max)

3.38

3.64

3.51

Ao (on end)

3.26

3.57

3.41

Ao (on off)

3.79

4.04

3.91

Spread of Flame

Class 1 to BS 476: Part 7: 1997 on non combustible surfaces

Fire Propagation


An index performance 1 of 1.2 and a sub-index i1 of 0 to BS 476: Part 6: 1989 on aluminium sheet. The combination of the fire propagation test and the spread of flame test gives Class '0' to the 1991 Building Regulations

M1 Classsification


Fire Tests according to French regulation 'Arrete' 28.9.1991.
Fire Number 9040722 CEMATE/1